Transmission and Measurement

When updating the measurement and/or transmission intervals for a device via public API it is important to keep in mind what valid configuration options are.

Transmission and measurement values are limited to the following: 5, 10, 20, 30, 60, 120, 360, and 720 minutes.

The measurement interval must be:

  1. Greater than one-sixth of the transmission interval
  2. Less than or equal to the transmission interval

For example, if the transmission interval is 360 minutes (6 hours), the measurement interval must be 60, 120, or 360 minutes (1, 2, or 6 hours).

The table below outlines what measurements intervals are compatible for a given transmission interval.

Transmission Intervals5 Minute Measurement10 Minute Measurement20 Minute Measurement30 Minute Measurement60 Minute Measurement120 Minute Measurement360 Minute Measurement720 Minute Measurement
5 minutes
10 minutes
20 minutes
30 minutes
60 minutes
120 minutes
360 minutes
720 minutes