Transmission and Measurement

When updating the measurement and/or transmission intervals for a device via public API it is important to keep in mind what valid configuration options are.

Transmission interval values are limited to the following: 5, 10, 20, 30, 60, 120, 360, 720, 1080 and 1440 minutes while the
Measurement interval values are limited to the following: 5, 10, 20, 30, 60, 120, 360, 720 minutes

The Measurement Interval shall be less or equal to the Transmission interval

The table below outlines the recommended combination of intervals

Transmission Intervals5 minutes Measurement10 minutes Measurement20 minutes Measurement30 minutes Measurement60 minutes Measurement120 minutes Measurement240 minutes Measurement360 minutes Measurement720 minutes Measurement
5 minutes✅✖✖✖✖✖✖✖✖
10 minutes✅✅✖✖✖✖✖✖✖
20 minutes✅✅✅✖✖✖✖✖✖
30 minutes✅✅Not advised✅✖✖✖✖✖
60 minutes✅✅✅✅✅✖✖✖✖
120 minutes✅✅✅✅✅✅✖✖✖
240 minutes✅✅✅✅✅✅✅✖✖
360 minutes✅✅✅✅✅✅Not advised✅✖
720 minutes✖✅✅✅✅✅✅✅✅
1080 minute✖✖✅✅✅✅✅✅Not advised
1440 minute✖✖✖✅✅✅✅✅✅